3B Scientific - page 157

. . . g o i n g o n e s t e p f u r t h e r
157
9985-1005624
Lungs
9985-1005652
Stomach
9985-1005653
Skin and Veins
9985-1005654
Options and Replacements for 9985-1005624
Intraosseous Leg Bones,
(pkg. of 10)
9985-1005655
Intraosseous Leg Skins,
(pkg. of 2)
9985-1005656
Femoral Injection Pad
9985-1005657
Interactive ECG-Simulator
This external unit allows defibrillator and pacer training directly on the
manikin. Training without a manikin is also possible). Various ECG rhythms
can be generated and displayed on an ECG-monitor (not included) for diag-
nostic and defibrillation training. All arrhythmias can be displayed in adult
or paediatric mode so that a total of 34 rhythms are available.
• The following 6 different arrhythmias are available for pacer training:
Sinus Brady, Junctional Brady, 2nd degree type I A-V block, 2nd degree
type II A-V block, 2nd degree type II A-V block with PVCs and 3rd degree
A-V block.
• Cardioversion can be simulated by defibrillating the manikin with a man-
ual, semi automatic, or automatic defibrillator. The following 11 arrhyth-
mias are available for defibrillator training: V. Fib, V. Tach (fast), V. Tach
(slow), V. Tach (polymorphic), A. Fib, A. Flutter, SVT, Sinus Tach, Sinus
rhythm with PVCs, Asystole and NSR.
• An LED illuminates for: pacer pulse detection, defibrillator discharge
detection, adult mode, paediatric mode and low battery. Battery saver
feature powers-off simulator automatically when not in use.
119 cm; 9 kg
E
9985-1005624
Child ACLS Manikin with Interactive Arrhythmia Simulator
This full body manikin of a 5 year old child offers a wide range of ACLS
training:
CPR
• Palpable and visual landmarks
• Fully articulated head, neck and jaw
Airway Management
• Realistic anatomy of the mouth, tongue, oral pharynx, larynx, epiglottis,
vocal cords, trachea and oesophagus
• Separate left and right lungs for auscultation
• Suctioning capabilities
• Oral, nasal and digital intubation capabilities
• Inflatable stomach bladder to indicate oesophageal intubation
I.v. Injection (at arm)
• Realistic size of an child’s veins
• Articulated at the biceps for antecubital and dorsal access
• Realistic flashback from a pressurized system
Blood Pressure Measurement
• Instructor determines systolic and diastolic levels, heart rate
and sound volume
• Speaker in arm reproduces real blood pressure sounds
• 5 Korotkoff phases can be turned on and off
• Auscultatory gap can be turned on and off
Intraosseous Infusion
• Palpable landmarks include the patella, tibia and tibial tuberosity
• Pressurized system allows aspiration of fluid
Femoral Access
• Palpable arterial pulse
• Palpable symphysis pubis and anterior superior iliac spine
• Realistic flashback from a pressurized system
Defibrillation Chest
• Internal load box absorbs full strength of every shock
• Manual, semi-automatic, automatic defibrillation
• Monitor manikin like a real patient at 4 ECG sites and 2 defibrillationsites
• Compatible with all standard brands and types of defibrillators and ECG-
monitors
Chi ld
Resusc i tat ion Advanced Techniques
1...,147,148,149,150,151,152,153,154,155,156 158,159,160,161,162,163,164,165,166,167,...184